Eaton | Innovative Technology Protector Series
The Eaton Innovative Technology Equalizer 2 Series is a surge protective device (SPD) designed to provide robust protection for critical electrical and electronic equipment. Here are its key features:
- Thermally Protected MOVs: Ensures safe operation by disconnecting under abnormal conditions, reducing risks like smoke damage.
- High Surge Current Capacity: Offers ratings up to 400 kA per phase, making it suitable for demanding applications.
- EMI/RFI Filtering: Protects sensitive equipment from electrical noise and disturbances.
- Wide Voltage Compatibility: Supports various voltage configurations for flexibility in installation.
- Compact Design: Ideal for commercial and industrial environments with space constraints.
This series is engineered to handle harsh electrical conditions, ensuring reliable performance and protection.
Protector Series specifications
Surge current capacity per phase (Standard) | 50, 80, 100, 120, 160, 200 kA ratings available |
Surge current capacity per phase (Legacy) | 48, 65, 80, 120, 160, 240, 300, 400 kA ratings available |
Nominal discharge current (In) | 20 kA |
Short-circuit current rating (SCCR) | 200 kA |
SPD type | UL 1449 5th edition and CSA Type 1 and Type 2 SPD |
Single-phase | 100, 110, 120, 127, 200, 208, 220, 230, 240, 277 |
Standard split-phase voltages available | 100/200, 110/220, 120/240, 127/254 |
Standard split-phase voltages available | 100/200, 110/220, 120/240, 127/254 |
Three-phase wye system voltages available | 100/175, 110/190, 120/208, 127/220, 220/380, 230/400, 240/415, 277/480, 305/525, 347/600 |
Three-phase delta system voltages | 200, 208, 220, 230, 240, 380, 400, 415, 440, 480, 525, 600 |
Three-phase high-leg delta system voltages | 120/240 |
Input power frequency | 50/60 Hz |
Protection modes | Single split-phase L-N, L-G, N-G, L-L Single-phase L-N, L-G, N-G Three-phase wye L-N, L-G, N-G, L-L Three-phase delta L-G, L-L Three-phase high-leg delta L-N, L-G, N-G, L-L, H-N, H-G, H-L |
Ports | 1 |
Operating temperature | –40 °C to +50 °C (–40 °F to +122 °F) S.M.A.R.T. models rated 0 °C to 50 °C (32 °F to 122 °F) |
Operating humidity | 5% through 95%, noncondensing |
Operating altitude | Up to 6561 ft (2000 m) |
Weight | 50–100 kA—approximately 6.8 kg (15 lb), 120–200 kA—approximately 9.1 kg (20 lb) |
Form C relay contact ratings | 125 Vac at 0.46 A, 30 Vdc at 1 A, terminal block connector rated 300 V, 1 A suitable for use with 26–16 AWG solid or stranded copper wire. Torque 5–7 lb-in |
Form C relay contact logic | Power on, normal state, NO contact = OPEN, NC contact = CLOSED Power off, fault state, NO contact = CLOSED, NC contact = OPEN |
Mounting feet torque rating | 20.3 lb-in (2.3 N•m) |
EMI/RFI filtering attenuation | Up to 40 dB from 10 kHz to 100 MHz |
Warranty | 15 years, 20 years if registered |
UL 96A compliant | Yes |
RoHS compliant | Yes |
NOM compliant | Yes |
Prop 65 compliant | Yes |
NFPA 780 compliant | Yes |
Wire length and AWG | Factory prewired with ~30 inches of #10 AWG wire |
Please contact us by email sales@ghitech.co.id for assistance and technical support. All questions are welcome!
Related Products
-
Capri ADE-1F2 DS – Double seal non-armored cable gland
The Capri ADE-1F2 DS is a widely approved cable gland for use with non-armored cables offering 2 outer sheath seals…
-
Ex-CELL Stainless Steel or Painted Steel Enclosures
High-Performance Ex-CELL Enclosures by Eaton Looking for robust, high-quality electrical enclosures? Eaton’s Ex-CELL Stainless Steel and Painted Steel Enclosures provide…
-
CEAG eLLK Non-metallic Hazardous Area Linear Fluorescent Light Fixtures
The Crouse-Hinds series eLLK fluorescent light fixture is an ideal source of general illumination, indoors or out, in hazardous environments…
-
Champ CPMV LED Hazardous Area Wallpack Light Fixtures
The Crouse-Hinds series Champ CPMV is uniquely engineered to provide a low profile wallpack solution for hazardous lighting applications. It’s…