Eaton CEAG GHG64 Ex d IIB Explosion-Protected Aluminum Panelboards
Eaton’s CEAG GHG64 Ex d IIB Explosion-Protected Aluminum Panelboards are engineered to provide safe and reliable electrical distribution in hazardous environments. These panelboards are certified for use in Zone 1 and Zone 21 areas, making them ideal for industries such as oil and gas, chemical processing, and mining. Below is an SEO-friendly overview of the GHG64 panelboards, their features, benefits, and applications.
Key Features of CEAG GHG64 Ex d IIB Aluminum Panelboards
- Explosion-Protected Design:
- Certified for use in Zone 1 and Zone 21 hazardous areas, where explosive gases, vapors, and dust may be present.
- Complies with IECEx and ATEX standards, ensuring safety in explosive environments.
- Robust Aluminum Construction:
- Made from high-quality aluminum that resists corrosion, impact, and extreme temperatures.
- Features flameproof enclosures to prevent ignition of surrounding hazardous substances.
- Modular Design:
- Allows for easy customization and integration of various electrical components, including circuit breakers, switches, and relays.
- Supports flexible configurations to meet specific project requirements.
- Environmental Protection:
- IP66-rated for protection against dust and water ingress, ensuring reliable operation in harsh conditions.
- Suitable for use in environments with high humidity, extreme temperatures, and corrosive substances.
- Easy Installation and Maintenance:
- Designed for quick and straightforward installation, reducing downtime during setup.
- Features removable panels and hinged doors for easy access to internal components.
Why Choose CEAG GHG64 Ex d IIB Aluminum Panelboards?
- Safety First: Certified for use in explosive environments, providing peace of mind in high-risk areas.
- Durability: Built to withstand harsh conditions, ensuring long-term reliability and performance.
- Customizable: Modular design allows for flexible configurations to meet specific application needs.
- Low Maintenance: Robust construction and easy access to components minimize maintenance requirements.
Applications of GHG64 Ex d IIB Aluminum Panelboards
- Oil and Gas: Offshore platforms, refineries, pipelines, and drilling rigs.
- Chemical Processing: Chemical plants, storage facilities, and industrial manufacturing.
- Mining: Underground mines and processing plants.
- Pharmaceuticals: Production facilities and laboratories.
- Food and Beverage: Processing plants and storage areas with explosive dust.
Technical Specifications
- Certifications: IECEx, ATEX.
- Protection Rating: IP66 for dust and water resistance.
- Temperature Range: Designed to operate in extreme temperatures.
- Enclosure Material: High-quality, corrosion-resistant aluminum.
- Customization: Available in various sizes and configurations.
Benefits of CEAG GHG64 Ex d IIB Aluminum Panelboards
- Explosion Protection: Safely contains and prevents ignition of explosive gases, vapors, and dust.
- Reliability: Engineered to perform in the harshest conditions, ensuring uninterrupted power distribution.
- Compliance: Meets global standards for hazardous area applications, including IECEx and ATEX.
- Cost-Effective: Reduces maintenance costs and extends equipment lifespan with its durable construction.
Why Trust CEAG GHG64 Ex d IIB Aluminum Panelboards?
Eaton’s CEAG GHG64 Ex d IIB Aluminum Panelboards are trusted by industries worldwide for their explosion-proof design, durability, and compliance with global safety standards. Whether you need reliable electrical distribution in oil refineries, chemical plants, or mining operations, these panelboards deliver exceptional performance in the most demanding environments.
Optimized Keywords:
CEAG GHG64 panelboards, Ex d IIB aluminum panelboards, explosion-proof electrical panels, hazardous area panelboards, ATEX IECEx certified panelboards, oil and gas electrical solutions, industrial panelboards, Zone 1 Zone 21 panelboards.
Ordering information
Catalog number | Product description |
GHG6401901R0201 | Ex-d control and distribution systems IIB: enclosure light alloy GHG 64 Size 1 |
GHG6401901R0202 | Ex-d control and distribution systems IIB + H2: enclosure light alloy GHG 64 Size 1 |
GHG6401901R0213 | Ex-d control and distribution systems IIB: enclosure light alloy GHG 64 Size 1 with hinge |
GHG6401901R0214 | Ex-d control and distribution systems IIB + H2: enclosure light alloy GHG 64 Size 1 with hinge |
GHG6401902R0201 | Ex-d control and distribution systems IIB: enclosure light alloy GHG 64 Size 2 |
GHG6401902R0202 | Ex-d control and distribution systems IIB + H2: enclosure light alloy GHG 64 Size 2 |
GHG6401902R0213 | Ex-d control and distribution systems IIB: enclosure light alloy GHG 64 Size 2 with hinge |
GHG6401902R0214 | Ex-d control and distribution systems IIB + H2: enclosure light alloy GHG 64 Size 2 with hinge |
GHG6401903R0201 | Ex-d control and distribution systems IIB: enclosure light alloy GHG 64 Size 3 |
GHG6401903R0202 | Ex-d control and distribution systems IIB + H2: enclosure light alloy GHG 64 Size 3 |
GHG6401903R0213 | Ex-d control and distribution systems IIB: enclosure light alloy GHG 64 Size 3 with hinge |
GHG6401903R0214 | Ex-d control and distribution systems IIB + H2: enclosure light alloy GHG 64 Size 3 with hinge |
GHG6401904R0201 | Ex-d control and distribution systems IIB: enclosure light alloy GHG 64 Size 4 |
GHG6401904R0202 | Ex-d control and distribution systems IIB + H2: enclosure light alloy GHG 64 Size 4 |
GHG6401904R0213 | Ex-d control and distribution systems IIB: enclosure light alloy GHG 64 Size 4 with hinge |
GHG6401904R0214 | Ex-d control and distribution systems IIB + H2: enclosure light alloy GHG 64 Size 4 with hinge |
GHG6401905R0201 | Ex-d control and distribution systems IIB: enclosure light alloy GHG 64 Size 5 |
GHG6401905R0202 | Ex-d control and distribution systems IIB + H2: enclosure light alloy GHG 64 Size 5 |
GHG6401905R0213 | Ex-d control and distribution systems IIB: enclosure light alloy GHG 64 Size 5 with hinge |
GHG6401905R0214 | Ex-d control and distribution systems IIB + H2: enclosure light alloy GHG 64 Size 5 with hinge |
GHG6401906R0201 | Ex-d control and distribution systems IIB: enclosure light alloy GHG 64 Size 6 |
GHG6401906R0202 | Ex-d control and distribution systems IIB + H2: enclosure light alloy GHG 64 Size 6 |
GHG6401906R0213 | Ex-d control and distribution systems IIB: enclosure light alloy GHG 64 Size 6 with hinge |
GHG6401906R0214 | Ex-d control and distribution systems IIB + H2: enclosure light alloy GHG 64 Size 6 with hinge |
GHG6401907R0201 | Ex-d control and distribution systems IIB: enclosure light alloy GHG 64 Size 7 |
GHG6401907R0202 | Ex-d control and distribution systems IIB + H2: enclosure light alloy GHG 64 Size 7 |
GHG6401907R0213 | Ex-d control and distribution systems IIB: enclosure light alloy GHG 64 Size 7 with hinge |
GHG6401907R0214 | Ex-d control and distribution systems IIB + H2: enclosure light alloy GHG 64 Size 7 with hinge |
GHG6401908R0201 | Ex-d control and distribution systems IIB: enclosure light alloy GHG 64 Size 8 |
GHG6401908R0202 | Ex-d control and distribution systems IIB + H2: enclosure light alloy GHG 64 Size 8 |
GHG6401908R0213 | Ex-d control and distribution systems IIB: enclosure light alloy GHG 64 Size 8 with hinge |
GHG6401908R0214 | Ex-d control and distribution systems IIB + H2: enclosure light alloy GHG 64 Size 8 with hinge |
GHG6401909R0201 | Ex-d control and distribution systems IIB: enclosure light alloy GHG 64 Size 9 |
GHG6401909R0202 | Ex-d control and distribution systems IIB + H2: enclosure light alloy GHG 64 Size 9 |
GHG6401909R0213 | Ex-d control and distribution systems IIB: enclosure light alloy GHG 64 Size 9 with hinge |
GHG6401909R0214 | Ex-d control and distribution systems IIB + H2: enclosure light alloy GHG 64 Size 9 with hinge |
GHG6401910R0201 | Ex-d control and distribution systems IIB: enclosure light alloy GHG 64 Size 10 |
GHG6401910R0202 | Ex-d control and distribution systems IIB + H2: enclosure light alloy GHG 64 Size 10 |
GHG6401910R0213 | Ex-d control and distribution systems IIB: enclosure light alloy GHG 64 Size 10 with hinge |
GHG6401910R0214 | Ex-d control and distribution systems IIB + H2: enclosure light alloy GHG 64 Size 10 with hinge |
GHG6401911R0201 | Ex-d control and distribution systems IIB: enclosure light alloy GHG 64 Size 11 |
GHG6401911R0202 | Ex-d control and distribution systems IIB + H2: enclosure light alloy GHG 64 Size 11 |
GHG6401911R0213 | Ex-d control and distribution systems IIB: enclosure light alloy GHG 64 Size 11 with hinge |
GHG6401911R0214 | Ex-d control and distribution systems IIB + H2: enclosure light alloy GHG 64 Size 11 with hinge |
GHG6409602P0001 | Rotary actuator for MCBs |
GHG6409603P0001 | Mushroom head pushbutton / emergency stop pushbutton D 36 mm with lock |
GHG6409603P0002 | Mushroom head pushbutton / emergency stop pushbutton D 50 mm with lock |
GHG6409604P0001 | Mushroom head pushbutton / emergency stop pushbutton with rotary latch |
GHG6409606P0001 | Mushroom head pushbutton / emergency stop pushbutton emergency stop pushbutton |
GHG6409607P0001 | Pushbutton yellow |
GHG6409607P0002 | Pushbutton blue |
GHG6409607P0003 | Pushbutton red |
GHG6409607P0004 | Pushbutton green |
GHG6409607P0005 | Pushbutton white |
GHG6409607P0006 | Pushbutton black |
GHG6409608P0001 | Key-operated pushbutton with 2 keys |
GHG6409612P0001 | Rotary actuator for 20A / 32-63A |
GHG6409614P0001 | Locking device pushbutton pressed |
GHG6409614P0001 | Signal lamp unit green |
GHG6409614P0001 | Locking device pushbutton unpressed |
GHG6409614P0002 | Signal lamp unit red |
GHG6409614P0003 | Locking device MCB actuator |
GHG6409614P0003 | Signal lamp unit yellow |
GHG6409614P0004 | Signal lamp unit blue |
GHG6409614P0005 | Signal lamp unit clear |
GHG6409617P0001 | Contact block 1 NO |
GHG6409617P0002 | Contact block 1 NC |
GHG6409617P0003 | Contact block 1 NO + 1 NC |
GHG6409617P0004 | Contact block 2 NO |
GHG6409617P0005 | Contact block 2 NC |
GHG6409617P0006 | Contact block 2 NO + 1 NC |
GHG6409617P0007 | Contact block 1 NO + 2 NC |
GHG6409617P0008 | Contact block 2 NO + 2 NC |
GHG6409617P0009 | Contact block 3 NO + 1 NC |
GHG6409617P0010 | Contact block 1 NO + 3 NC |
GHG6409617P0011 | Contact block 4 NO |
GHG6409617P0012 | Contact block 4 NC |
NOR000001170030 | Ex-d built-in components IIB: rotary actuator for main switch, main switch, 63A to < 100A |
NOR000001170031 | Ex-d built-in components IIB: rotary actuator for main switch, main switch, 100A to < 250A |
NOR000001170032 | Ex-d built-in components IIB: rotary actuator for main switch, main switch, 250A to < 1000A |
GHG2601004R0005 | Ex-d built-in components IIC: main switch up to 180A, 20A, 3-pole |
GHG2601004R0006 | Ex-d built-in components IIC: main switch up to 180A, 20A, 4-pole |
GHG2601005R0005 | Ex-d built-in components IIC: main switch up to 180A, 40A, 3-pole |
GHG2601005R0006 | Ex-d built-in components IIC: main switch up to 180A, 40A, 4-pole |
GHG2601007R0003 | Ex-d built-in components IIC: main switch up to 180A, 125A, 3-pole |
GHG2601007R0004 | Ex-d built-in components IIC: main switch up to 180A, 125A, 4-pole |
GHG2601008R0003 | Ex-d built-in components IIC: main switch up to 180A, 180A, 3-pole |
GHG2601008R0004 | Ex-d built-in components IIC: main switch up to 180A, 180A, 4-pole |
GHG6101940R0001 | Ex-d built-in components IIC: NH 00 main fuse up to 125A, equipped without signal contact, 2A – 125A |
GHG6101940R0002 | Ex-d built-in components IIC: NH 00 main fuse up to 125A, equipped with signal contact (1 change-over), 2A – 125A |
GHG236060020 | Control switch GHG 23 enclosure mounting |
GHG236062020 | Control switch GHG 23 enclosure mounting |
GHG236065010 | Control switch GHG 23 enclosure mounting |
GHG296060020 | Control switch GHG 29 enclosure mounting |
GHG296062020 | Control switch GHG 29 enclosure mounting |
GHG296065010 | Control switch GHG 29 enclosure mounting |
AK1-2 | Ex-d control and distribution systems IIC: Ex-e steel-connection / bus bar box size 1 – 10 |
AK1-2 | Ex-d control and distribution systems IIC: Ex-e steel-connection box size 1 |
AK2-2 | Ex-d control and distribution systems IIC: Ex-e steel-connection box size 2 |
AK4-1 | Ex-d control and distribution systems IIC: Ex-e steel-connection box size 4 |
AK5-1 | Ex-d control and distribution systems IIC: Ex-e steel-connection box size 5 |
AK6-1 | Ex-d control and distribution systems IIC: Ex-e steel-connection box size 6 |
SSK1 | Ex-d control and distribution systems IIC: Ex-e steel-bus-bar box size 1 |
SSK2 | Ex-d control and distribution systems IIC: Ex-e steel-bus-bar box size 2 |
SSK3 | Ex-d control and distribution systems IIC: Ex-e steel-bus-bar box size 4 |
SSK4 | Ex-d control and distribution systems IIC: Ex-e steel-bus-bar box size 5 |
Please contact us by email sales@ghitech.co.id for assistance and technical support. All questions are welcome!
Related Products
-
Eaton Crouse-Hinds Quick-Lok™ AC/MC & FMC Connectors
The Eaton Crouse-Hinds Quick-Lok™ connectors are fast-installation fittings designed for AC, MC, and FMC cable systems. These connectors feature a…
-
CEAG AB05 LED Explosion-protected Light Fixtures
A flameproof and impact-resistant wallpack for lighting outdoor pathways, walkways and corridors in hazardous areas. The CEAG AB05 explosion-protected wallpack…
-
Capri ADE-1F2 Anchorage – Strain relief non-armored cable gland
The ADE1-F2 Anchorage is a widely approved cable gland for use with non-armored cables featuring additional mechanical strain relief. Suitable…
-
Eaton Crouse-Hinds ACC Series Combination Couplings – AC/MC to EMT
The Eaton Crouse-Hinds ACC Series Combination Couplings are designed to connect EMT conduit to armored cable (AC), metal-clad (MC) cable,…