CEAG eXlink Hazardous Area Hot Swap Connectors Pre-assembled to Terminal Boxes by Eaton
CEAG eXlink Hazardous Area Hot Swap Connectors, pre-assembled to terminal boxes, are the ideal solution for safe and efficient electrical connections in hazardous environments. Engineered for Zones 1 and 21, these connectors allow for quick and easy hot swapping without the need for additional wiring or system shutdowns. Key features include hot swap capability, compatibility with Ethernet and Fast Ethernet-Bus cables, and pre-assembled connectors wired on terminals for up to 7-pole connections.
Choose from polyamide, nickel-plated brass, or stainless steel enclosures to suit your specific application needs. With a nominal current of up to 16A per connector, these connectors ensure reliable performance and significant time and cost savings during service and repair work.
Ordering information
Catalog number | Product description |
GHG7311201R5001 | GHG 73112 with 3 x receptacle GHG 571 8108 R000x, 08 h, 1 x M25 Ex-i, 12 x 2.5 mm² |
GHG7311201R5002 | GHG 73112 with 1 x inlet GHG 574 9103 R000x, 06 h, 1 x inlet GHG 574 9110 R000x, 10 h, 2 x M20, 8 x 2.5 mm², 2 x PE/PA |
GHG7910101R5006 | GHG 79101 with 2 x receptacle GHG 574 8110 R000x, 10 h, 2 x M20, 4 x 2.5 mm², 1 x PE/PA |
GHG7910101R5106 | GHG 79101 with 2 x receptacle GHG 574 8110 R300x, 10 h, 2 x M20, 4 x 2.5 mm², 1 x PE/PA |
GHG7910101R5201 | GHG 79101 with 1 x receptacle GHG 571 8108 R000x, 08 h, 2 x M20, 1 x M20 screw plug, 4 x 2.5 mm², 1 x PE/PA |
GHG7910101R5202 | GHG 79101 with 1 x receptacle GHG 571 8108 R000x, 08 h, 1 x M20, 4 x 2.5 mm², 1 x PE/PA |
GHG7910101R5203 | GHG 79101 with 1 x receptacle GHG 574 8110 R000x, 10 h, 1 x M25, 4 x 2.5 mm², 1 x PE/PA |
GHG7910101R5204 | GHG 79101 with 1 x receptacle GHG 571 8212 R000x, 12 h, 1 x M20, 2 x 2.5 mm², 1 x PE/PA |
GHG7910101R5206 | GHG 79101 with 1 x receptacle GHG 571 8106 R000x, 06 h, 2 x M20, 1 x M20 screw plug, 4 x 2.5 mm², 1 x PE/PA |
GHG7910101R5208 | GHG 79101 with 1 x receptacle GHG 571 8208 R000x, 08 h, 2 x M20, 1 x M20 screw plug, 4 x 2.5 mm², 1 x PE/PA |
GHG7910101R5210 | GHG 79101 with 1 x receptacle lockable GHG 574 8110 R090x, 10 h, 1 x M25, 4 x 2.5 mm², 1 x PE/PA |
GHG7910101R5212 | GHG 79101 with 1 x receptacle GHG 571 8112 R000x, 12 h, 1 x M20, 1 x M20 screw plug, 2 x 2.5 mm², 1 x PE/PA |
GHG7910101R5213 | GHG 79101 with 1 x receptacle GHG 571 8108 R000x, 08 h, 1 x M20, 4 x 2.5 mm², 1 x PE/PA |
GHG7910101R5214 | GHG 79101 with 1 x receptacle GHG 571 8106 R000x, 06 h, 1 x M20, 2 x 2.5 mm², 1 x PE/PA |
GHG7910101R5215 | GHG 79101 with 1 x receptacle GHG 574 8105 R000x, 05 h, 1 x M25, 6 x 2.5 mm², 1 x PE/PA |
GHG7910101R5216 | GHG 79101 with 1 x receptacle GHG 571 8106 R000x, 06 h, 1 x M20, 2 x 2.5 mm², 1 x PE/PA |
GHG7910101R5217 | GHG 79101 with 1 x receptacle GHG 571 8208 R000x, 08 h, 1 x M25, 4 x 2.5 mm², 1 x PE/PA |
GHG7910101R5218 | GHG 79101 with 1 x receptacle GHG 571 9108 R300x, 08 h, 2 x M12, 4 x 2.5 mm², 1 x PE/PA |
GHG7910101R5219 | GHG 79101 with 1 x inlet GHG 571 9106 R000x, 06 h, 1 x M20, 4 x 2.5 mm², 1 x PE/PA |
GHG7910101R5220 | GHG 79101 with 1 x receptacle GHG 571 8208 R300x, BUS Ex-i 02 h, 1 x M20 Ex-i, 4 x 2.5 mm², 1 x PE/PA |
GHG7910101R5221 | GHG 79101 with 1 x receptacle GHG 571 8108 R300x, BUS Ex-i 08 h, 1 x M20 Ex-i, 4 x 2.5 mm², 1 x PE/PA |
GHG7910101R5222 | GHG 79101 with 1 x inlet GHG 571 9108 R000x, 08 h, 1 x M20, 4 x 2.5 mm², 1 x PE/PA |
GHG7910101R5223 | GHG 79101 with 1 x inlet GHG 574 9105 R000x, 05 h, 2 x M16, 4 x 2.5 mm², 1 x PE/PA |
GHG7910101R5224 | GHG 79101 with 1 x receptacle GHG 571 8108 R000x, BUS Ex-i 08 h, 1 x M20 Ex-i, 4 x 2.5 mm², 1 x PE/PA |
GHG7910101R5226 | GHG 79101 with 1 x receptacle GHG 571 8102 R300x, 02 h and 1 x receptacle GHG 571 8108 R300x, 08 h, 2 x M20, 8 x 2.5 mm², 1 x PE/PA |
GHG7910101R5227 | GHG 79101 with GHG 571 8102 R000x, BUS 02 h, 2 x M20, 1 x M20 screw plug, 4 x 2.5 mm², 1 x PE/PA |
GHG7910101R5228 | GHG 79101 with GHG 574 8101 R000x, BUS Ethernet 01h, 1 plug GHG5747101R0001 enclosed, 1 x M12, 2 x 2.5 mm², 1 x PE/PA |
GHG7910201R5001 | GHG 79102 with 3 x receptacle GHG 571 8106 R 000x, 06 h, 1 x M25, 5 x 2.5 mm, 2 x PE/PA |
GHG7910201R5002 | GHG 79102 with 1 x receptacle GHG 571 8108 R000x, 08 h 1 x receptacle GHG 571 8112 R000x, 12 h, 1 x M20 Ex-i, 12 x 2.5 mm², 1 x PE/PA |
GHG7910201R5003 | GHG 79102 with 1 x receptacle GHG 574 8210 R000x, 10 h, 3 x M25, 12 x 2.5 mm², 2 x PE/PA |
GHG7910201R5004 | GHG 79102 with 1 x receptacle GHG 574 8210 R000x, 10 h, 1 x M25, 1 x M25 screw plug, 4 x 2.5 mm², 1 x PE/PA |
GHG7910201R5005 | GHG 79102 with 2 x receptacle GHG 571 8106 R000x, 06 h, 2 x M20 trumpet shape, 2 x M20 screw plug, 6 x 2.5 mm², 2 x PE/PA |
GHG7910201R5006 | GHG 79102 with 2 x receptacle GHG 574 8110 R300x, 10 h, 2 x M25, 8 x 2.5 mm², 2 x PE/PA |
GHG7910201R5007 | GHG 79102 with 2 x receptacle GHG 571 8206 R000x, 06 h, 2 x M25, 4 x 2.5 mm², 2 x PE/PA |
GHG7910201R5008 | GHG 79102 with 1 x receptacle GHG 572 8108 R300x, 08 h, 2 x M16, 12 x 2.5 mm², 2 x PE/PA |
GHG7910201R5009 | GHG 79102 with 1 x receptacle GHG 571 8112 R000x, 12 h, 1 x M20, 1 x M25, 8 x 2.5 mm², 1 x PE/PA |
GHG7910201R5011 | GHG 79102 with 1 x receptacle GHG 571 8108 R000x, 08 h, 1 x M16 Ex-i, 1 x M16 screw plug, 1 x M20 Ex-i, 6 x 2.5 mm², 1 x PE/PA |
Brand | CEAG |
---|
Please contact us by email sales@ghitech.co.id for assistance and technical support. All questions are welcome!
Related Products
-
Eaton Crouse-Hinds Quick-Lok™ AC/MC & FMC Connectors
The Eaton Crouse-Hinds Quick-Lok™ connectors are fast-installation fittings designed for AC, MC, and FMC cable systems. These connectors feature a…
-
CEAG eLLK Non-metallic Hazardous Area Linear LED Light Fixtures
The Crouse-Hinds series CEAG eLLK LED light fixture is an ideal source of general illumination, indoors or out, in Zone…
-
Eaton Crouse-Hinds Clamps, Anti-Short Bushings & Metal Stud Grommets
Eaton Crouse-Hinds offers a complete line of clamps, anti-short bushings, and metal stud grommets designed for use with Armored Cable…
-
Eaton Crouse-Hinds ACC Series Combination Couplings – AC/MC to EMT
The Eaton Crouse-Hinds ACC Series Combination Couplings are designed to connect EMT conduit to armored cable (AC), metal-clad (MC) cable,…