CEAG GHG7 Ex e Non-metallic Junction and Terminal Boxes
Eaton’s Crouse-Hinds series CEAG GHG7 junction and terminal boxes are designed for measuring and controlling utilization in Ex-e and Ex-i applications. They are used as a link between the main cable to the control room and the branch cables into the field. They can also be used for the direct connection of actuators and sensors.
Manufactured to meet the most demanding harsh and hazardous area environmental applications, GHG7 boxes are a globally certified enclosure for Zones 1, 2, 21 and 22 areas.
Constructed of polyamide, the GHG7 is offered in multiple enclosure sizes to suit customer preferences.
Certifications and compliances
- Zones 1, 2, 21, 22
GHG 791 models
- Marking accd. to 94/9/EC: Ex II 2 G Ex dem ia II, IIC T6; Ex II 2 D Ex tD A21 IP66 T80°C
- EC-Type Examination Certificate: PTB 00 ATEX 3108
- IECEx Certificate of Conformity: IECEx BKI 07.0034
- Marking accd. to IECEx: Ex e II T6 / Ex ia IIC T6; Ex tD A21 IP66 T58°C
- Permissible ambient temperature: -20°C to +40°C (standard); -55°C to +40°C (optional)
- Protection class: I
- Degree of protection accd. to EN 60529: IP66
GHG 731 models
- Marking accd. to 94/9/EC: Ex II 2 G Ex e IIC T4/T5/T6 Gb; Ex II 2 D Ex tb IIIC T80°C/T95°C Db IP6X
- EC-Type Examination Certificate: BVS 13 ATEX E 037X
- IECEx Certificate of Conformity: IECEx BVS 13.0045X
- Marking accd. to IECEx: Ex e IIC T6/T5 Gb; Ex tb IIIC T80°C/T95°C Db IP6X
- Permissible ambient temperature: -20°C to +40°C (standard); -55°C to +55°C (optional)
- Protection class: I
- Degree of protection accd. to EN 60529: IP66
GHG 721 models
- Marking accd. to 94/9/EC: Ex II 2 G Ex e IIC T4/T5/T6 Gb; Ex II 2 D Ex tb IIIC T80°C/T95°C Db IP6X
- EC-Type Examination Certificate: BVS 13 ATEX 013X
- IECEx Certificate of Conformity: IECEx BVS 13.0031X
- Marking accd. to IECEx: Ex e IIC T4/T5 Gb; Ex tb IIIC T80°C/T95°C/ Db IP6X
- Permissible ambient temperature: -20°C to +40°C (standard); -55°C to +55°C (optional)
- Protection class: I
- Degree of protection accd. to EN 60529: IP66
GHG 744 models
- Marking accd. to 94/9/EC: Ex II 2 G Ex e IIC T4/T5/T6 Gb / Ex e ib [ia/ib] IIC T4/T5/T6 Gb; Ex II 2 D Ex tb IIIC T80°C/T95°C Db IP6X
- EC-Type Examination Certificate: BVS 12 ATEX E 118X
- IECEx Certificate of Conformity: IECEx BVS 12.0071X
- Marking accd. to IECEx: Ex e IIC T4/T5/T6 Gb; Ex tb IIIC T80°C/T95°C Db IP6X
- Permissible ambient temperature: -20°C to +40°C (standard); -55°C to +55°C (optional)
- Protection class: I
- Degree of protection accd. to EN 60529: IP66
GHG 746 models
- Marking accd. to 94/9/EC: Ex II 2 G Ex e IIC T4/T5/T6 Gb / Ex e ib [ia/ib] IIC T4/T5/T6 Gb; Ex II 2 D Ex tb IIIC T80°C/T95°C Db IP6X
- EC-Type Examination Certificate: BVS 12 ATEX E 118X
- IECEx Certificate of Conformity: IECEx BVS 12.0071X
- Marking accd. to IECEx: Ex e IIC T4/T5/T6 Gb; Ex tb IIIC T80°C/T95°C Db IP6X
- Permissible ambient temperature: -20°C to +40°C (standard); -55°C to +55°C (optional)
- Protection class: I
- Degree of protection accd. to EN 60529: IP66
Design features
Terminal boxes
- International approvals
- Decisive cost saving with the CEAG installation system
- IP66 safety standard
- Freely accessible connection terminals
- Clip-in flange technique
- Snap-out terminal rails
- Internal coating for EMC-protection on request
Junction boxes
- International approvals
- Decisive cost reduction with the CEAG mounting system
- Free accessible connection terminals
- IP66 safety standard
- Version for metal entries available
Standard materials
- Enclosure – black polyamide (GHG 791 models); black fiberglass-reinforced polyester (GHG 721, GHG 731, GHG 744 and GHG 746 models)
Ordering information
Catalog number | Product description |
GHG7910101R0001 | Junction box Ex-e 791 01 2 x M25 |
GHG7910101R0002 | Junction box Ex-e 791 01 4 x M25 |
GHG7910101R0019 | Junction box Ex-e 791 01 4 x M20 |
GHG7910101R0068 | Junction box Ex-e 791 01 4 x M20, cage clamp terminal |
GHG7910101R0069 | Junction box Ex-e 791 01 4 x M25, cage clamp terminal |
GHG7910201R0001 | Junction box Ex-e 791 02 6 x M25 |
GHG7910201R0002 | Junction box Ex-e 791 02 6 x M32 |
GHG7910201R0003 | Junction box Ex-e 791 02 6 x M20 |
GHG7910201R0006 | Junction box Ex-e 791 02 4 x M25 |
GHG7910201R0007 | Junction box Ex-e 791 02 4 x M32 |
GHG7910101R0003 | Terminal box Ex-e 791 01 1 x M25/1 x M25 drillings |
GHG7910101R0004 | Terminal box Ex-i 791 01 1 x M25/1 x M25 |
GHG7910101R0005 | Terminal box Ex-e 791 01 1 x M25/2 x M12 |
GHG7910101R0006 | Terminal box Ex-i 791 01 1 x M25/1 x M12 |
GHG7910101R0008 | Terminal box Ex-i 791 01 1 x M25/1 x M25 |
GHG7910101R0009 | Terminal box Ex-e 791 01 1 x M25/2 x M12 |
GHG7910101R0010 | Terminal box Ex-i 791 01 1 x M25/1 x M12 |
GHG7910201R0008 | Terminal box Ex-e 791 02 1 x M25/1 x M12 |
GHG7910201R0009 | Terminal box Ex-i 791 02 1 x M25/1 x M32 |
GHG7910201R0010 | Terminal box Ex-e 791 02 1 x M25/4 x M12 |
GHG7910201R0011 | Terminal box Ex-i 791 02 1 x M25/4 x M12 |
GHG7910201R0013 | Terminal box Ex-i 791 02 1 x M25/1 x M32 |
GHG7910201R0014 | Terminal box Ex-e 791 02 1 x M25/4 x M12 |
GHG7910201R0015 | Terminal box Ex-i 791 02 1 x M25/4 x M12 |
GHG7311102R0531 | Terminal box Ex-e 731 11 without drilling/1 x Ex-e*/UK 3 N/7 x PE |
GHG7311102R1088 | Terminal box Ex-e 731 11 without drilling/14 x Ex-e/UK 5 N/7 x PE |
GHG7311102R1485 | Terminal box Ex-e 731 11 4 x M25/16 x Ex-e/UK 3 N/7 x PE |
GHG7311202R0387 | Terminal box Ex-e 731 12 without drilling/1 x Ex-e1)/UK 3 N/14 x PE |
GHG7311202R0976 | Terminal box Ex-e 731 12 without drilling/24 x Ex-e/UK 5 N/14 x PE |
GHG7311202R1345 | Terminal box Ex-e 731 12 6 x M25/28 x Ex-e/UK 3 N/14 x PE |
GHG7210001R0001 | Terminal box Ex-e 721 00 without drilling |
GHG7210001R0005 | Terminal box Ex-e 721 00 1 x M32/3 x M32 |
GHG7210001R0006 | Terminal box Ex-i 721 00 1 x M32/3 x M32 |
GHG7210001R0007 | Terminal box Ex-e 721 00 1 x M32/12 x M20 |
GHG7210001R0008 | Terminal box Ex-i 721 00 1 x M32/12 x M20 |
GHG7210001R0010 | Terminal box Ex-i 721 00 1 x M32/3 x M32 |
GHG7210001R0011 | Terminal box Ex-e 721 00 1 x M32/12 x M20 |
GHG7210001R0012 | Terminal box Ex-i 721 00 1 x M32/12 x M20 |
GHG7211001R0003 | Terminal box Ex-e 721 10 without drilling |
GHG7211001R0004 | Terminal box Ex-e 721 10 1 x M40/24 x M20 |
GHG7211001R0013 | Terminal box Ex-i 721 10 1 x M40/6 x M32 |
GHG7211001R0015 | Terminal box Ex-i 721 10 1 x M40 /24 x M20 |
GHG7211001R0017 | Terminal box Ex-i 721 10 1 x M40/6 x M32 |
GHG7211001R0018 | Terminal box Ex-e 721 10 1 x M40/24 x M20 |
GHG7211001R0019 | Terminal box Ex-i 721 10 1 x M40/24 x M20 |
GHG7440101R0005 | Terminal box Ex-e 744 01 without drilling |
GHG7450201R0004 | Terminal box Ex-e 745 02 without drilling |
GHG7450201R0012 | Terminal box Ex-i 745 02 1 x M50/8 x M32 |
GHG7450201R0013 | Terminal box Ex-e 745 02 1 x M50/30 x M16 |
GHG7450201R0014 | Terminal box Ex-i 745 02 1 x M50/30 x M16 |
GHG7450201R0015 | Terminal box Ex-e 745 02 1 x M50/24 x M20 |
GHG7450201R0016 | Terminal box Ex-i 745 02 1 x M50/8 x M32 |
GHG7450201R0017 | Terminal box Ex-e 745 02 1 x M50/30 x M16 |
GHG7450201R0018 | Terminal box Ex-i 745 02 1 x M50/30 x M16 |
GHG7450201R0020 | Terminal box Ex-e 745 02 1 x M50/24 x M20 |
GHG7450201R0021 | Terminal box Ex-i 745 02 1 x M50/24 x M20 |
GHG7450201R0022 | Terminal box Ex-i 745 02 1 x M50/24 x M20 |
GHG7460301R0002 | Terminal box Ex-e 746 03 2 x plastic flange |
GHG7490401R0001 | Terminal box Ex-e 749 04 3 x plastic flange |
GHG6101953R0101 | Mounting plate Size 1 fUr Wall mounting |
GHG6101953R0102 | Mounting plate Size 1 fUr Pipe mounting |
GHG6101953R0103 | Mounting plate Size 1 fUr Trellis mounting |
GHG6101953R0104 | Mounting plate Size 2 fUr Wall mounting |
GHG6101953R0105 | Mounting plate Size 2 fUr Pipe mounting |
GHG6101953R0106 | Mounting plate Size 2 fUr Trellis mounting |
GHG6101953R0107 | Mounting plate Size 2A fUr Wall mounting |
GHG6101953R0108 | Mounting plate Size 2A fUr Pipe mounting |
GHG6101953R0109 | Mounting plate Size 2A fUr Trellis mounting |
GHG6101955R0101 | Protection canopy for mounting plate size 1 |
GHG6101955R0102 | Protection canopy for mounting plate size 2 |
GHG6101955R0103 | Protection canopy for mounting plate size 2A |
GHG6101955R0104 | Protection canopy for mounting plate size 3 |
GHG6101955R0105 | Protection canopy for mounting plate size 3A |
GHG6101955R0106 | Protection canopy for mounting plate size 3B |
GHG6101955R0107 | Protection canopy for mounting plate size 4 |
GHG6101955R0108 | Protection canopy for mounting plate size 5 |
Brand | CEAG |
---|
Please contact us by email sales@ghitech.co.id for assistance and technical support. All questions are welcome!
Related Products
-
Capri ADE-1F2 DS – Double seal non-armored cable gland
The Capri ADE-1F2 DS is a widely approved cable gland for use with non-armored cables offering 2 outer sheath seals…
-
CEAG eLLK Non-metallic Hazardous Area Linear Fluorescent Light Fixtures
The Crouse-Hinds series eLLK fluorescent light fixture is an ideal source of general illumination, indoors or out, in hazardous environments…
-
Eaton Crouse-Hinds ACC Series Combination Couplings – AC/MC to EMT
The Eaton Crouse-Hinds ACC Series Combination Couplings are designed to connect EMT conduit to armored cable (AC), metal-clad (MC) cable,…
-
Capri ADE-1F2 Anchorage – Strain relief non-armored cable gland
The ADE1-F2 Anchorage is a widely approved cable gland for use with non-armored cables featuring additional mechanical strain relief. Suitable…