CEAG GHG60 IEC Ex e Explosion-protected Distribution Board Enclosures
Eaton’s Crouse-Hinds series CEAG GHG60 explosion-protected enclosures provide IEC Ex e protection in harsh and hazardous areas.
Available in fiberglass-reinforced polyester and electropolished stainless steel, the GHG60 is offered in multiple enclosure sizes to suit customer preferences. Cable entries, extensions or bus bar systems can also be added as desired.
Certifications and compliances
- Marking accd. to 94/9/EC: Ex II 2 G Ex e IIC Gb Ex de IIC T6, T5, T4; Ex II 2 D Ex tb IIIC Db Ex tD A21 IP66 T80°C, T95°C*
- EC-Type Examination Certificate: PTB 99 ATEX 3118U
- IECEx Certificate of Conformity: IECEx-PTB11.0030U
- Marking accd. to IECEx: Ex e IIC Gb / Ex tb IIIC Db
- Operating temperature range: -20°C up to +95°C (standard); -55°C up to +95°C (optional)
- Protection class: I
- Degree of protection accd. to EN 60529: IP66
- Marking accd. to 94/9/EC: Ex II 2 G Ex e IIC Gb Ex de IIC T6, T5, T4; Ex II 2 D Ex tb IIIC Db Ex tD A21 IP66 T80°C, T95°C*
- EC-Type Examination Certificate: PTB 99 ATEX 3118U
- IECEx Certificate of Conformity: IECEx-PTB11.0030U
- Marking accd. to IECEx: Ex e IIC Gb; Ex tb IIIC Db
- Operating temperature range: -20°C up to +95°C (standard); -55°C up to +95°C (optional)
- Protection class: I
- Degree of protection accd. to EN 60529: IP66
* The limits of the operating temperature range and the max. permissible temperature rise of the components must be taken into account.
Design features
- Modular slip-on assembly
- High IP66 protection
- Snap-on components
- Retrofitting
Standard materials
- Enclosure – fiberglass-reinforced polyester or electropolished AISI 316L stainless steel
Ordering information
Catalog number | Product description |
GHG6000101R0001 | Ex-e empty enclosure in plastic design: Size 1: 1 mounting space 106 mm, cover closed |
GHG6000201R0001 | Ex-e empty enclosure in plastic design: Size 2: 1 mounting space 213 mm, cover closed |
GHG6000301R0001 | Ex-e empty enclosure in plastic design: Size 2: 1 mounting space 213 mm, cover raised for insertion of main switch = 80A |
GHG6000401R0001 | Ex-e empty enclosure in plastic design: Size 3: 2 mounting space 213 mm, cover closed |
GHG6000501R0001 | Ex-e empty enclosure in plastic design: Size 3: 2 mounting space 213 mm, cover raise for insertion of main switch = 80A to 180A |
GHG6000601R0001 | Ex-e empty enclosure in plastic design: Size 4: 3 mounting space 213 mm, cover closed |
GEH0010161 | Ex-e empty enclosure in plastic design: Size 1: 1 mounting space 106 mm, cover cut-out with actuating flap for GHG 61 |
GEH0010162 | Ex-e empty enclosure in plastic design: Size 1: 1 mounting space 106 mm, cover cut-out with actuating flap for GHG 62 |
GEH0020161 | Ex-e empty enclosure in plastic design: Size 2: 1 mounting space 213 mm, cover cut-out with 1 actuating flap for GHG 61 |
GEH0020162 | Ex-e empty enclosure in plastic design: Size 2: 1 mounting space 213 mm, cover cut-out with 1 actuating flap for GHG 62 |
GEH0030161 | Ex-e empty enclosure in plastic design: Size 3: 2 mounting space 213 mm, cover cut-out with 1 actuating flap for GHG 61 |
GEH0030162 | Ex-e empty enclosure in plastic design: Size 3: 2 mounting space 213 mm, cover cut-out with 1 actuating flap for GHG 62 |
GEH0030261 | Ex-e empty enclosure in plastic design: Size 3: 2 mounting space 213 mm, cover cut-out with 2 actuating flaps for GHG 61 |
GEH0030262 | Ex-e empty enclosure in plastic design: Size 3: 2 mounting space 213 mm, cover cut-out with 2 actuating flaps for GHG 62 |
GEH00303 | Ex-e empty enclosure in plastic design: Size 3: 2 mounting space 213 mm, cover with 1 actuating flap and main switch = 40A |
GEH0040161 | Ex-e empty enclosure in plastic design: Size 4: 3 mounting space 213 mm, cover cut-out with 1 actuating flap for GHG 61 |
GEH0040162 | Ex-e empty enclosure in plastic design: Size 4: 3 mounting space 213 mm, cover cut-out with 1 actuating flap for GHG 62 |
GEH0040261 | Ex-e empty enclosure in plastic design: Size 4: 3 mounting space 213 mm, cover cut-out with 2 actuating flaps for GHG 61 |
GEH0040262 | Ex-e empty enclosure in plastic design: Size 4: 3 mounting space 213 mm, cover cut-out with 2 actuating flaps for GHG 62 |
GEH0040361 | Ex-e empty enclosure in plastic design: Size 4: 3 mounting space 213 mm, cover cut-out with 3 actuating flaps for GHG 61 |
GEH0040362 | Ex-e empty enclosure in plastic design: Size 4: 3 mounting space 213 mm, cover cut-out with 3 actuating flaps for GHG 62 |
GEH00404 | Ex-e empty enclosure in plastic design: Size 4: 3 mounting space 213 mm, cover with 2 actuating flaps and main switch = 40A |
GEH10000 | Ex-e empty enclosure in stainless steel design: Size 1: 1 mounting space 106 mm, cover closed |
GEH1000161 | Ex-e empty enclosure in stainless steel design: Size 1: 1 mounting space 106 mm, cover cut-out with small actuating flap for GHG 61 |
GEH1000162 | Ex-e empty enclosure in stainless steel design: Size 1: 1 mounting space 106 mm, cover cut-out with small actuating flap for GHG 62 |
GEH20000 | Ex-e empty enclosure in stainless steel design: Size 2: 1 mounting space 213 mm, cover closed |
GEH2000161 | Ex-e empty enclosure in stainless steel design: Size 2: 1 mounting space 213 mm, cover cut-out with 1 actuating flap for GHG 61 |
GEH2000162 | Ex-e empty enclosure in stainless steel design: Size 2: 1 mounting space 213 mm, cover cut-out with 1 actuating flap for GHG 62 |
GEH30000 | Ex-e empty enclosure in stainless steel design: Size 3: 2 mounting space 213 mm, cover closed |
GEH3000161 | Ex-e empty enclosure in stainless steel design: Size 3: 2 mounting space 213 mm, cover cut-out with 1 actuating flap for GHG 61 |
GEH3000162 | Ex-e empty enclosure in stainless steel design: Size 3: 2 mounting space 213 mm, cover cut-out with 1 actuating flap for GHG 62 |
GEH3000261 | Ex-e empty enclosure in stainless steel design: Size 3: 2 mounting space 213 mm, cover cut-out with 2 actuating flaps for GHG 61 |
GEH3000262 | Ex-e empty enclosure in stainless steel design: Size 3: 2 mounting space 213 mm, cover cut-out with 2 actuating flaps for GHG 62 |
GEH30003 | Ex-e empty enclosure in stainless steel design: Size 3: 2 mounting space 213 mm, cover with 1 actuating flap and main switch = 40A |
GEH40000 | Ex-e empty enclosure in stainless steel design: Size 4: 3 mounting space 213 mm, cover closed |
GEH4000161 | Ex-e empty enclosure in stainless steel design: Size 4: 3 mounting space 213 mm, cover cut-out with 1 actuating flap for GHG 61 |
GEH4000162 | Ex-e empty enclosure in stainless steel design: Size 4: 3 mounting space 213 mm, cover cut-out with 1 actuating flap for GHG 62 |
GEH4000261 | Ex-e empty enclosure in stainless steel design: Size 4: 3 mounting space 213 mm, cover cut-out with 2 actuating flaps for GHG 61 |
GEH4000262 | Ex-e empty enclosure in stainless steel design: Size 4: 3 mounting space 213 mm, cover cut-out with 2 actuating flaps for GHG 62 |
GEH4000361 | Ex-e empty enclosure in stainless steel design: Size 4: 3 mounting space 213 mm, cover cut-out with 3 actuating flaps for GHG 61 |
GEH4000362 | Ex-e empty enclosure in stainless steel design: Size 4: 3 mounting space 213 mm, cover cut-out with 3 actuating flaps for GHG 62 |
GEH40004 | Ex-e empty enclosure in stainless steel design: Size 4: 3 mounting space 213 mm, cover with 2 actuating flaps and main switch = 40A |
Brand | CEAG |
---|
Please contact us by email sales@ghitech.co.id for assistance and technical support. All questions are welcome!
Related Products
-
Capri ADE accessories
Eaton’s Capri hazardous-area ADE series cable glands have a broad range of dedicated accessories to support installation and provide additional…
-
Capri ADE-1F2 DS – Double seal non-armored cable gland
The Capri ADE-1F2 DS is a widely approved cable gland for use with non-armored cables offering 2 outer sheath seals…
-
CEAG RLF Recessed Mount Hazardous Area Linear LED Fixtures
Eaton’s Crouse-Hinds series RLF recessed mounted LED linear fixtures are designed for flush and surface mounting in Zone 1, 2,…
-
Capri ADCS & ADCC – Cable glands for flexible & rigid conduits
The ADCC and ADCS is a widely approved cable gland for use connecting a cable and conduit system. With a…