Applications

  • Used in hazardous areas where a flexible connection is needed for:
    • Difficult bends
    • Movement or vibration in connected equipment

Key Features

  • Explosionproof & Rugged Design – Withstands high pressures and mechanical abuse.
  • Liquidtight – Suitable for wet locations.
  • No Bonding Jumpers Required – Metallic braid ensures a continuous electrical path.
  • Wire Duct Liner (1/2” to 2”) – Prevents grounding faults and short circuit burn-through.

Certifications & Compliance

  • NEC Certified:
    • 1/2” & 3/4”: Class I, Division 1, Groups A, B, C, D.
    • 1” to 2”: Class I, Division 1, Groups C, D.
    • All sizes: Class II, Division 1, Groups E, F, G; Class III.
  • UL1203 Listed for lengths up to 36”.
  • ATEX & IECEx (ECGJH S516 only):
    • 1/2” & 3/4” (4” to 36” length) – Ex d IIC, IP66.
    • 1” to 2” (4” to 36” length) – Ex d IIB, IP66.

Materials & Construction

  • 1/2” to 2”:
    • End fittings: Forged brass.
    • Inner core: Flexible brass with bronze braid covering.
    • Packing: Woven cotton braid impregnated with asphalt.
  • 2-1/2” to 4”:
    • End fittings: Stainless steel (304).
    • Braid covering: Stainless steel.

Description

Applications

  • Used in hazardous areas where a flexible connection is needed for:
    • Difficult bends
    • Movement or vibration in connected equipment

Key Features

  • Explosionproof & Rugged Design – Withstands high pressures and mechanical abuse.
  • Liquidtight – Suitable for wet locations.
  • No Bonding Jumpers Required – Metallic braid ensures a continuous electrical path.
  • Wire Duct Liner (1/2” to 2”) – Prevents grounding faults and short circuit burn-through.

Certifications & Compliance

  • NEC Certified:
    • 1/2” & 3/4”: Class I, Division 1, Groups A, B, C, D.
    • 1” to 2”: Class I, Division 1, Groups C, D.
    • All sizes: Class II, Division 1, Groups E, F, G; Class III.
  • UL1203 Listed for lengths up to 36”.
  • ATEX & IECEx (ECGJH S516 only):
    • 1/2” & 3/4” (4” to 36” length) – Ex d IIC, IP66.
    • 1” to 2” (4” to 36” length) – Ex d IIB, IP66.

Materials & Construction

  • 1/2” to 2”:
    • End fittings: Forged brass.
    • Inner core: Flexible brass with bronze braid covering.
    • Packing: Woven cotton braid impregnated with asphalt.
  • 2-1/2” to 4”:
    • End fittings: Stainless steel (304).
    • Braid covering: Stainless steel.

Ordering Information

ECGJH Couplings (Male Threaded Ends)

Flexible Length (in.) Hub Size Catalog #
4 1/2” ECGJH14
4 3/4” ECGJH24
6 1/2” ECGJH16
6 3/4” ECGJH26
6 1” ECGJH36
8 1/2” ECGJH18
8 3/4” ECGJH28
8 1” ECGJH38
10 1/2” ECGJH110
10 3/4” ECGJH210
10 1” ECGJH310
12 1/2” ECGJH112
12 3/4” ECGJH212
12 1” ECGJH312
12 1-1/4” ECGJH412
12 1-1/2” ECGJH512
12 2” ECGJH612
15 1/2” ECGJH115
15 3/4” ECGJH215
15 1” ECGJH315
15 1-1/4” ECGJH415
15 1-1/2” ECGJH515
15 2” ECGJH615
18 1/2” ECGJH118
18 3/4” ECGJH218
18 1” ECGJH318
18 1-1/4” ECGJH418
18 1-1/2” ECGJH518
18 2” ECGJH618
27 2-1/2” ECGJH727
27 3” ECGJH827
27 4” ECGJH1027

ECLK Couplings (One Male, One Female Union)

Flexible Length (in.) Hub Size Catalog #
4 1/2” ECLK14
4 3/4” ECLK24
6 1/2” ECLK16
6 3/4” ECLK26
6 1” ECLK36
8 1/2” ECLK18
8 3/4” ECLK28
8 1” ECLK38
10 1/2” ECLK110
10 3/4” ECLK210
10 1” ECLK310
12 1/2” ECLK112
12 3/4” ECLK212
12 1” ECLK312
12 1-1/4” ECLK412
12 1-1/2” ECLK512
12 2” ECLK612
15 1/2” ECLK115
15 3/4” ECLK215
15 1” ECLK315
15 1-1/4” ECLK415
15 1-1/2” ECLK515
15 2” ECLK615
18 1/2” ECLK118
18 3/4” ECLK218
18 1” ECLK318
18 1-1/4” ECLK418
18 1-1/2” ECLK518
18 2” ECLK618
27 2-1/2” ECLK727
27 3” ECLK827
27 4” ECLK1027

Custom Lengths & Options

  • All Stainless Steel Construction (Suffix: S516 – Available for ECGJH only).
  • Flexible PVC Protective Coating (Suffix: S758 – For corrosive environments).
  • Special Lengths Available (up to 144 inches). To order, change the last two digits in the catalog number to the desired length in whole inches (e.g., ECGJH2110 for a 3/4” hub, 110-inch length).

Conclusion

The Crouse-Hinds EC Explosionproof Couplings offer reliable, flexible, and explosionproof connections for hazardous environments. Available in multiple lengths and hub sizes, they provide durability and compliance with NEC, UL, ATEX, and IECEx standards.

For additional details or custom orders, contact your local supplier or visit Eaton’s official website.

 

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare